Manual of Human Angiopoietin Receptor Tie1 (ANG-R-Tie1) ELISA

<

Our company is a supplier of ELISA kits. The price is fair. The pre-sale, in-sale and after-sale services are at your service. Provide free test service, please call us!

Human Angiopoietin Receptor Tie1 (ANG-R-Tie1) Enzyme Linked Immunoassay (ELISA)

Kit instruction manual

This reagent is for research use only

Purpose: This kit is used to determine the content of angiopoietin receptor Tie1 (ANG-R-Tie1) in human serum, plasma and related liquid samples.

Experimental principle:

This kit uses the double antibody sandwich method to determine the level of human angiopoietin receptor Tie1 (ANG-R-Tie1) in the specimen. Microporous plates were coated with purified human angiogenin receptor Tie1 (ANG-R-Tie1) antibody to prepare solid-phase antibodies. Angiopoietin receptor Tie1 (ANG-R) was sequentially added to the monoclonal antibody-coated microwells -Tie1), then combined with the HRP-labeled angiogenin receptor Tie1 (ANG-R-Tie1) antibody to form an antibody-antigen-enzyme-labeled antibody complex, and after thorough washing, the substrate TMB is added for color development. TMB is converted into blue under the catalysis of HRP enzyme, and into the final yellow under the action of acid. The color depth is positively correlated with the angiogenin receptor Tie1 (ANG-R-Tie1) in the sample. The absorbance (OD value) was measured with a microplate reader at a wavelength of 450 nm, and the concentration of human angiogenin receptor Tie1 (ANG-R-Tie1) in the sample was calculated by a standard curve.

Kit composition:

Kit composition

48 hole configuration

96-well configuration

save

Instructions

1 serving

1 serving

Sealing film

2 pieces (48)

2 pieces (96)

sealed bag

1

1

Enzyme coated plate

1 × 48

1 × 96

Store at 2-8 ℃

Standard product: 2700ng / L

0.5ml × 1 bottle

0.5ml × 1 bottle

Store at 2-8 ℃

Standard dilution

1.5ml × 1 bottle

1.5ml × 1 bottle

Store at 2-8 ℃

Enzyme reagent

3 ml × 1 bottle

6 ml × 1 bottle

Store at 2-8 ℃

Sample diluent

3 ml × 1 bottle

6 ml × 1 bottle

Store at 2-8 ℃

Developer A liquid

3 ml × 1 bottle

6 ml × 1 bottle

Store at 2-8 ℃

Developer B liquid

3 ml × 1 bottle

6 ml × 1 bottle

Store at 2-8 ℃

Stop solution

3ml × 1 bottle

6ml × 1 bottle

Store at 2-8 ℃

Concentrated washing liquid

(20ml × 20 times) × 1 bottle

(20ml × 30 times) × 1 bottle

Store at 2-8 ℃

Sample processing and requirements:

1. Serum: room temperature blood coagulates naturally for 10-20 minutes, centrifuged for about 20 minutes (2000-3000 rpm). Collect the supernatant carefully and centrifuge again if a precipitate appears during storage.

2. Plasma: EDTA or sodium citrate should be selected as the anticoagulant according to the requirements of the specimen, mixed for 10-20 minutes, and centrifuged for about 20 minutes (2000-3000 rpm). Collect the supernatant carefully. If a precipitate forms during storage, it should be centrifuged again.

3. Urine: collected in a sterile tube and centrifuged for about 20 minutes (2000-3000 rpm). Collect the supernatant carefully. If a precipitate forms during storage, centrifuge again. Pleural and ascites, cerebrospinal fluid reference implementation.

4. Cell culture supernatant: When detecting secreted components, collect with a sterile tube. Centrifuge for about 20 minutes (2000-3000 rpm). Collect the supernatant carefully. When detecting the components inside the cells, dilute the cell suspension with PBS (PH7.2-7.4), and the cell concentration will reach about 1 million / ml. Through repeated freezing and thawing, the cells are destroyed and the intracellular components are released. Centrifuge for about 20 minutes (2000-3000 rpm). Collect the supernatant carefully. If a precipitate forms during storage, it should be centrifuged again.

5. Organize the specimen: after cutting the specimen, weigh it. Add a certain amount of PBS, PH7.4. Quickly freeze and save with liquid nitrogen for later use. After the specimen melts, it still maintains a temperature of 2-8 ° C. Add a certain amount of PBS (PH7.4) and homogenize the specimen with a manual or homogenizer. Centrifuge for about 20 minutes (2000-3000 rpm). Collect the supernatant carefully. After aliquoting, a portion is to be tested, and the rest is frozen for future use.

6. The specimen should be extracted as soon as possible after collection. The extraction should be carried out according to relevant literature. If the test cannot be performed immediately, the specimen can be stored at -20 ℃, but repeated freezing and thawing should be avoided.

7. The sample containing NaN3 cannot be detected because NaN3 inhibits the activity of horseradish peroxidase (HRP).

Steps

1. Dilution and loading of standard products: set 10 standard wells on the enzyme-coated plate, add 100 μl of the standard products in the first and second wells, and then add the standard products in the first and second wells. 50μl of diluent, mix well; then take 100μl from the first well and the second well and add them to the third and fourth wells respectively, and then add 50μl of standard diluent to the third and fourth wells respectively, mix well; Then take 50μl each in the third and fourth wells and discard it, then add 50μl each to the fifth and sixth wells, and then add 50ul of the standard dilution solution to the fifth and sixth wells respectively, and mix well; After mixing, take 50μl from the fifth and sixth wells and add them to the seventh and eighth wells respectively. Then add 50μl of the standard dilution solution to the seventh and eighth wells respectively. Take 50μl from the eight wells and add them to the ninth and tenth wells. Then add 50μl of the standard dilution solution to the ninth and tenth wells. After mixing, take 50μl from the ninth and tenth wells and discard. (After dilution, the volume of each well is 50μl, and the concentration is 1800ng / L, 1200ng / L, 600ng / L, 300ng / L, 150ng / L)

2. Add samples: set up blank wells (the blank control wells do not add samples and enzyme reagents, the rest of the steps are the same) and the sample wells to be tested. Add 40μl of sample diluent to the test sample well of the enzyme-coated plate, and then add 10μl of the test sample (the final dilution of the sample is 5 times). Add the sample and add the sample to the bottom of the well of the microplate, try not to touch the wall of the well, shake gently to mix.

3. Incubation: Seal the plate with a sealing plate and incubate at 37 ° C for 30 minutes.

4. Mixing solution: Dilute 30 times (20 times of 48T) concentrated washing liquid with distilled water 30 times (20 times of 48T) and then use.

5. Washing: Carefully peel off the sealing film, discard the liquid, spin dry, fill each well with the washing liquid, let it stand for 30 seconds and then discard, repeat 5 times and pat dry.

6. Add enzyme: add 50μl of enzyme label reagent to each well, except blank well.

7. Incubation: The operation is the same as 3.

8. Washing: The operation is the same as 5.

9. Color development: add 50μl of developer A to each well, then add 50μl of developer B, mix gently, and develop at 37 ° C in the dark for 15 minutes.

10. Termination: Add 50μl of stop solution to each well to stop the reaction (at this time the blue will turn to yellow).

11. Determination: Measure the absorbance (OD value) of each well in sequence with the blank air conditioner at zero and 450 nm wavelength. The measurement should be carried out within 15 minutes after adding the stop solution.

Precautions:

1. The kit should be equilibrated at room temperature for 15-30 minutes before being taken out of the refrigerated environment. If the enzyme label coated plate is unopened, the strip should be stored in a sealed bag.

2. Crystals may be precipitated in the concentrated washing liquid, which can be heated and dissolved in a water bath during dilution, and the results will not be affected during washing.

3. The sampler should be used at each step of sample addition, and the accuracy should be regularly checked to avoid test errors. It is best to control the sampling time within 5 minutes. If there are many specimens, it is recommended to use a volley gun to add samples.

4. Please make a standard curve at the same time of each measurement, it is best to make a double hole. If the content of the test substance in the specimen is too high (the OD value of the sample is greater than the OD value of the first well of the standard well), please first dilute it with a certain multiple (n times) of the sample diluent and then determine it. When calculating, please multiply the total dilution Multiple (× n × 5).

5. The sealing film is limited to one-time use to avoid cross-contamination.

6. Please keep the substrate away from light.

7. Strictly follow the instructions, and the test results must be determined by the microplate reader.

8. All samples, washing liquids and various wastes should be treated as infectious agents.

9. The components of different batches of this reagent shall not be mixed.

10. If there is any difference with the English manual, the English manual shall prevail.

Calculation:

Taking the concentration of the standard as the abscissa and the OD value as the ordinate, draw a standard curve on the coordinate paper, and find the corresponding concentration from the standard curve according to the OD value of the sample; then multiply it by the dilution factor; Calculate the linear regression equation of the standard curve with the OD value, substitute the OD value of the sample into the equation, calculate the sample concentration, and multiply it by the dilution factor to obtain the actual concentration of the sample.

Kit performance:

1. The correlation coefficient R between the linear regression of the sample and the expected concentration is above 0.95.

2. The batch and approval shall be less than 9% and 11% respectively

examination range:

100ng / L -2000ng / L

Storage conditions and validity period:

1. Store the kit: 2-8 ℃.

2. Validity: 6 months

Our Cement bag /sand bag/ pp woven sack /PP woven bag/PP big bag/Jumbo Bags' specification are as below:

1) the Cement Bags character are dust-proof, moisture-proof, bear the radiation, safety and substance.
2) Enough intensity on structure, convenient to load and discourage, suit mechanical load and unload.
3) Concrete Bags Widely used in chemical industry, cement, corn, mineral products and other powdery, granular and massive goods 'packing
4) Marks such as logos and names of the goods can be printed on the bags on client'requests (bag concrete custom).

Our company covers an area of 10000 square meters, 2000 square meters' Plant. We have over 180 employees presently, including 20 technician, The main equipment include a composite machine, bag-making machine and a four-color printing machine and some corresponding equipment, And we introduced an advanced sewing bag equipment units(German bag making technology), Paper Bags can be made reach up to 80 centimeters wide, 136 cm length on integration production(Punching-Agglutination-Suture) With six color printing bag-making machine units, And we use environmental printing ink and UV device, we can meet the market demand for high quality printing during bag concrete custom. Our company passed the ISO - 9001 quality system certification and ISO9001: 2000 international quality system certification, the company controls all production link quality strictly according to the system standard and implements policy ISO quality spirit, integrates brand, service, price, information, so as to we make the packaging gain reliance deeply. 


We mainly focus on Cement Bags, Concrete Bags, paper bags, Kraft Paper Bag, paper-plastic compound bag, color printing bag, paper-aluminum composite valve pocket, heat sealing bag, sewing bag, square bottom bag, Shanghai kraft paper bag, Shanghai valve pocket, carrier bags, plastic bag, etc., our production widely used in chemical raw materials, new building materials, fodder, food, flour and other industry demand, we also make bags for Leaves, white carbon black and animals food sack(powdery and granular products). We have more than 20 million production capacity annual output. Company can also provide customized scheme for the market, transact all kinds of commodity inspection certification and latent assurance certification.


bag concrete custom

Cement Bags

Pp Woven Cement Bag,Kraft Paper Cement Bag,Concrete Bag,Premixed Concrete Bags

WenZhou JinYuan Packing Manufacture Co.,Ltd , https://www.tote-shoppingbag.com